Espessura da Web - A espessura da seção central vertical que conecta os dois flanges - varia de altura para o aço canal S355JR, com variações típicas de 3,0 mm (U50) a 14,0 mm (U400). Exemplos incluem:
Canais pequenos: u50x37x4.5 (espessura da teia de 4,5 mm), U70x45x5 (espessura da web de 5,0 mm)
Canais médios: U120x53x5.5 (espessura da web 5,5 mm), U200x73x7 (espessura da web 7,0 mm)
Large channels: U300x90x10 (10.0 mm web thickness), U400x140x14 (14.0 mm web thickness)The web's primary role is to resist shear forces- lateral forces acting parallel to the channel's cross-section (e.g., wind loads, seismic activity). Thicker webs provide higher shear capacity, making them suitable for short-span channels supporting heavy loads. Thinner webs are used in long-span applications where bending (not shear) is the primary load, as they reduce weight without compromising bending strength. EN 10025-2:2004 specifies web thickness tolerances: ±0.4 mm for thicknesses ≤5 mm, ±0.5 mm for 5.1–10 mm, and ±0.6 mm for >10 mm. Essas tolerâncias garantem que a Web possa transferir com segurança as forças de cisalhamento entre os flanges, impedindo a falha prematura.